Common solutions for: Freezer runs all the time

01 - Room Temperature is Hot
Normal operating room temperatures for a freezer are between 60° and 95° Fahrenheit (16° and 35° Celsius). The hotter and more humid the air is the less efficient the freezer will be, causing it to run more. If possible, keep the freezer within the recommended operating temperatures and as cool as possible.
Top Solution
02 - Sealed System Leak
If the freezer only freezes the top shelf, there may be a sealed system leak in one of the shelves. Sealed system repairs are usually cost-prohibitive. If the sealed system is leaking, you will probably need to replace the freezer.
Top Solution
03 - Temperature Control Thermostat
The temperature control thermostat directs voltage to the compressor, evaporator fan motor, and condenser fan motor. If the temperature control thermostat is not working properly, it can cause the freezer to run continuously. To determine if the thermostat is defective, rotate the thermostat from the lowest setting to the highest setting and listen for a “click.” If you hear a click, the thermostat is not likely defective. If you do not hear a click, use a multimeter to test the thermostat for c...ontinuity. If the contacts inside the thermostat do not open, even at the lowest settings, this indicates that the thermostat is defective. If the temperature control thermostat is defective, replace it.
Top Solution
04 - Door Not Fully Closing
Check to see that the doors are closing properly. If a door bin or food item is keeping the door open slightly the freezer may not cool properly, which can cause the freezer to run all the time.
Common
05 - Condenser Coils are Dirty
If the condenser coils are located within the freezer walls, the coils do not require cleaning. However, if the condenser coils can be readily accessed from behind or under the unit, you should clean them every 6 to 12 months by using a soft bristle brush (or a dedicated condenser coil cleaning brush) to wipe off the coils in a circular motion. A vacuum cleaner with a nozzle attachment can also be used for hard-to-reach areas.
Common
06 - Sealed System Leak
If the freezer only freezes the top shelf, there may be a sealed system leak in one of the shelves. Sealed system repairs are usually cost-prohibitive. If the sealed system is leaking, you will probably need to replace the freezer.
Uncommon But Possible