Step By Step Instructions

1
Before you replace the fuel shut-off valve on your generator first make sure the engine has cooled then remove the wire and boot from the spark plug to prevent the engine from accidentally starting.
2
We recommend performing this procedure with no fuel in the tank.
3
Use pliers to release the retaining clamp securing the fuel line to the shut-off valve and pull the line off.
4
Now use a 14 mm wrench to help unthread the old shut-off valve from the fuel tank.
5
Prepare the new fuel shut-off valve for installation by positioning the locking nut approximately a half-inch from the end of the threads.
6
Now thread the new valve into the fuel tank then tighten the nut to secure.
7
Attach the fuel line to the new valve and secure it with the retaining clamp.
8
Reattach the wire and boot to the spark plug fill the tank with fuel and your generator should be ready for use.
Description
This video provides step-by-step repair instructions for replacing the fuel shut off valve on a Briggs and Stratton generator. The most common reason for replacing the fuel shut off valve is when the generator won’t start.

All of the information for this fuel shut off valve replacement video is applicable to the following brands:
Briggs & Stratton

Tools used: pliers, flat head screwdriver, 14mm wrench
Step-By-Step Instructions
1
Before you replace the fuel shut-off valve on your generator first make sure the engine has cooled then remove the wire and boot from the spark plug to prevent the engine from accidentally starting.
2
We recommend performing this procedure with no fuel in the tank.
3
Use pliers to release the retaining clamp securing the fuel line to the shut-off valve and pull the line off.
4
Now use a 14 mm wrench to help unthread the old shut-off valve from the fuel tank.
5
Prepare the new fuel shut-off valve for installation by positioning the locking nut approximately a half-inch from the end of the threads.
6
Now thread the new valve into the fuel tank then tighten the nut to secure.
7
Attach the fuel line to the new valve and secure it with the retaining clamp.
8
Reattach the wire and boot to the spark plug fill the tank with fuel and your generator should be ready for use.

Applicable Product Model

Parts Needed
Total$0.00

Related Articles & Videos

04:17
How It Works
How Does a Generator Work? — Engine Repair Tips
02:46
Part Replacement
Briggs & Stratton Generator Dies? Voltage Regulator 207840GS
03:14
Part Replacement
Briggs & Stratton Generator Replace Circuit Breaker #209676GS
02:22
Part Replacement
Briggs & Stratton Generator Muffler Replacement #189008GS
01:54
Part Replacement
Briggs Stratton Generator Won't Start? Spark Arrestor 83083GS