Mtr blr 1/230 1/3
Grid is 1 inch square
1083044 Blower Motor
Manufacturer Part

1083044 Blower Motor

Genuine OEM Part # 1083044Alternative Part Number(s)
Manufacturer Part
Mtr blr 1/230 1/3
Grid is 1 inch square
1083044 Blower Motor
$1,363.64
Loading stock status
Loading stock status
Does this part fit my product?
Find your model number or log in to select it from your saved machines.
Mtr blr 1/230 1/3
Loading stock status
$1,363.64
start a live chat with Repair Clinic customer support

This part 1083044 is compatible with:

Product Type:
Air Handler, Central Air Conditioner, Furnace, Packaged Unit/RTU

Related Articles & Videos

02:28
Troubleshooting
Furnace Blower Not Running — Furnace Troubleshooting
01:49
Troubleshooting
Furnace Noisy Or Loud — Furnace Troubleshooting
00:45
Troubleshooting
Replace Furnace Filters - Tech Tips from Repair Clinic
02:47
Troubleshooting
Furnace Starts Then Stops — Furnace Troubleshooting
02:01
Troubleshooting
Central Air Conditioner Fan Motor Not Running — Central Air Conditioner Troubleshooting
Frequently Bought with Blower Motor
5303935066 Igniter
297286803 Run Capacitor

Blower Motor Customer Reviews

Common Problems Fixed by the Blower Motor

Based on customer reports and repair data, this part commonly fixes these issues:

Very Likely

Furnace blower not running

Likely

Furnace is noisy or loud

Likely

Central air conditioner not blowing enough

Likely

Central air conditioner coil icing up

Likely

Furnace not blowing enough

Likely

Air handler is noisy or loud

Likely

Heat pump not cooling

Likely

Heat pump not heating

Likely

Heat pump coils frosting up

Likely

Furnace circuit breaker keeps tripping

Likely

Air handler circuit breaker keeps tripping

Likely

Air handler blower not running/not turning on

Likely

Air handler is not blowing enough

Likely

Air handler coil icing up

Likely

Strange smells coming from furnace

Likely

Air handler has a burning smell

Likely

Air handler not cooling properly

Likely

Central air conditioner circuit breaker keeps tripping

Likely

Heat pump circuit breaker keeps tripping

Possible

Air handler not heating

Possible

Furnace not heating

Possible

Central air conditioner not cooling properly

About the Blower Motor

The blower motor blows air through the return vent, past the heat exchanger, and into the home’s venting. First, make sure that power is getting to the motor. If power is getting to the blower motor, but the motor does not run, the motor may be burned out. If the blower motor is burned out, replace it. If the blower motor hums, check the blower fan to ensure that it spins freely. If the blower fan is unobstructed but does not spin freely, replace the blower motor.

Alternative Part Number(s)

Replaces Part Number R65BA0051