Choose Product
Identify Problem
03
Find Solutions

Sharp Microwave not working

When your Sharp microwave is not working, start with the line fuse, which can blow when too much current passes through the circuitry and leave the microwave dead or not turning on. Test the fuse for continuity, but also identify the underlying fault or a replacement fuse may blow again. Next, inspect the switch holder behind the control panel. If it is damaged or misaligned, the door switches may not actuate correctly when the door closes, so the microwave may have power but not work. A defective main control board can also cause a Sharp microwave to stop working, although it is less common and should be considered only after testing other parts. An overheated or failed thermostat, a blown thermal fuse, or an electrical outlet with no incoming power are additional possible causes. Enter your model number to find the exact replacement line fuse, switch holder, control board, thermostat, or thermal fuse for your Sharp microwave. Any repair that requires opening the outer cabinet must be handled with extreme care because the high-voltage capacitor can store a lethal charge even after the microwave is unplugged. Proper capacitor discharge is required before interior work, and a qualified technician should perform the repair if you are not familiar with that procedure.

01 - Sharp Microwave Line Fuse

If too much current passes through the microwave circuitry, the line fuse will blow. If the line fuse blows, the microwave won’t start. To determine if the line fuse is at fault, use a multimeter to test it for continuity. If the fuse does not have continuity, replace it. In addition, you should investigate and resolve the problem that caused the fuse to blow. If you don’t resolve the underlying issue, the new fuse will blow too. (Caution: The microwave oven can store thousands of volts of electricity in its high voltage capacitor, even after the microwave oven has been unplugged. Due to the potential for electric shock, i...t is extremely dangerous to replace the electronic components in a microwave. Only a licensed technician should replace the line fuse.)
Enter model number to search for the required part specific to your product
Top Solution

02 - Sharp Microwave Switch Holder

The microwave switch holder is the component that houses the door switches behind the control panel. If the switch holder is damaged or misaligned, one of more switches may not be actuated when the microwave door is closed, resulting in the microwave not working. You will need to uninstall the control panel and inspect the switch holder to confirm it is in good condition and secured properly. Replace the switch holder with a new one if necessary.
Top Solution

03 - Sharp Microwave Main Control Board

The main control board might be defective. However, this is rarely the case. Control boards are often misdiagnosed—check all of the more commonly defective parts. If you have determined that all of the other components are working properly,replace the main control board. (Caution: The microwave oven can store thousands of volts of electricity in its high voltage capacitor, even after the microwave oven has been unplugged. Due to the potential for electric shock, it is extremely dangerous to replace the electronic components in a microwave. Only a licensed technician should replace the main control board.)
Top Solution

04 - Sharp Microwave Thermostat

If the microwave overheats, the thermostat trips to cut off voltage to the microwave. If the thermostat is shorted open, it may not allow voltage to reach the high voltage components. To determine if the thermostat is at fault, use a multimeter to test it for electrical continuity. If the thermostat does not have continuity, and it cannot be reset, replace it.
Highly Likely

05 - Incoming Power Problem

The electrical outlet may not be getting power. To determine if the outlet is getting power, try plugging something else into the outlet. If the outlet is not getting power, check the home circuit breakers or fuses.
Highly Likely

06 - Sharp Microwave Thermal Fuse

The thermal fuse cuts off power to the microwave if the microwave overheats. To determine if the thermal fuse has blown, use a multimeter to test it for continuity. If the fuse does not have continuity, replace it. The thermal fuse cannot be reset—if the fuse is blown, it must be replaced. (Caution: The microwave oven can store thousands of volts of electricity in its high voltage capacitor, even after the microwave oven has been unplugged. Due to the potential for electric shock, it is extremely dangerous to replace the electronic components in a microwave. Only a licensed technician should replace the thermal fuse.)
Common

07 - Sharp Microwave Control Board

Since the control board controls the voltage being sent to all of the microwave's components, a defective board could be responsible for a microwave not working. However, this is rarely the case. Control boards are often misdiagnosed—check all of the more commonly defective parts. If you have determined that all of the other components are working properly, replace the control board.
Common

Frequently Asked Questions

Why is my Sharp microwave not working but it has power?
Where is the Sharp microwave fuse, and how do I replace it?
Can a Sharp microwave door switch cause the microwave to stop working?
Why does my Sharp microwave keep shutting off or stop working after it runs?
How do I find the correct Sharp microwave replacement part?