Choose Product
Identify Problem
03
Find Solutions

RCA Dryer light is out

If your RCA dryer's interior light is out, the simplest culprit is a bad light socket: a multimeter can confirm whether voltage is reaching the socket and a failed socket is an easy replacement. If the socket checks out, the most likely follow-ups are failures in the control assemblies — the control panel, touchpad or user control/display board all contain indicator lamps and must be replaced as complete assemblies when their lights fail — so a faulty control or touchpad will look like dryer controls not working. Less commonly the door switch will prevent power from reaching the lamp; test the switch for continuity while actuated and replace it if it does not close. Finally, a damaged light assembly or bulb itself can be the issue, so inspect the lens and bulb for burn marks and replace as needed. If you need a part, enter your model number on RepairClinic.com to see the exact replacement part that fits your dryer.

01 - RCA Dryer Light Socket

If the light itself is newly installed or shows no signs of damage, yet still won't work, it's possible the light socket is defective. You can use a multimeter to test whether or not voltage is reaching the light socket. If the meter shows that power is reaching the light socket then it's likely the socket is malfunctioning and will need to be replaced.
Enter model number to search for the required part specific to your product
Top Solution

02 - RCA Dryer Control Panel

The dryer control panel indicator lights are part of the control panel assembly and cannot be replaced separately. If an control panel indicator light is not working, the entire control panel assembly will need to be replaced.
Highly Likely

03 - RCA Dryer Touchpad and Control Panel

The dryer control panel indicator lights are part of the touchpad and control panel and cannot be replaced separately. If an control panel indicator light is not working, the entire touchpad and control panel assembly will need to be replaced.
Highly Likely

04 - RCA Dryer User Control and Display Board

The dryer control panel indicator lights are part of the user control and display board and cannot be replaced separately. If an control panel indicator light is not working, the user control and display board will need to be replaced.
Highly Likely

05 - RCA Dryer Door Switch

The dryer door switch will turn the interior light off when the door is closed and turn it back on when the door is opened. If the switch is defective, it may be unable to allow voltage to reach the light. You can use a multimeter to test the door switch for appropriate electrical continuity when actuated. If the switch doesn't provide appropriate continuity, it will need to be replaced.
Less Common

06 - RCA Dryer Light Assembly

The most likely cause of a dryer interior light not working is a defective light assembly. Inspect the assembly for any visible damage or burn marks and replace as required.
Less Common

07 - RCA Dryer Light Bulb

The most likely cause of a dryer interior light not working is a burned out light bulb. Inspect the bulb for a broken filament or burn marks inside the glass and replace the bulb as required.
Less Common

Frequently Asked Questions

Dryer lights flashing: Why is my dryer interior light out?
Dryer controls not working: Could the control panel or touchpad be the reason the light isn’t working?
Dryer door won't close: Can a bad door switch prevent the interior light from turning on?
How can I test the dryer light socket with a multimeter?
How do I enter my model number on RepairClinic.com to find and buy the correct replacement part?