Choose Product
Identify Problem
03
Find Solutions

Roper Dryer light is out

If your Roper dryer light is out, start by checking the bulb and the light socket: a bad socket can stop voltage from reaching the lamp even when the wiring looks fine, and you can verify that with a multimeter. If the socket and bulb test good, the next most likely causes are electronics in the front panel—indicator lights are built into the control panel, touchpad, or user control and display board, and those assemblies often have to be replaced as complete units when their lights fail. A faulty door switch is less common but can prevent the interior light from getting power, so test its continuity while actuating it. A damaged light assembly is also a possibility, so inspect for burn marks or broken contacts. If you need the right replacement part, enter your dryer model number on RepairClinic.com to pull up the exact light socket, control panel, touchpad, user control board, door switch, or light assembly that fits your machine.

01 - Roper Dryer Light Socket

If the light itself is newly installed or shows no signs of damage, yet still won't work, it's possible the light socket is defective. You can use a multimeter to test whether or not voltage is reaching the light socket. If the meter shows that power is reaching the light socket then it's likely the socket is malfunctioning and will need to be replaced.
Enter model number to search for the required part specific to your product
Top Solution

02 - Roper Dryer Control Panel

The dryer control panel indicator lights are part of the control panel assembly and cannot be replaced separately. If an control panel indicator light is not working, the entire control panel assembly will need to be replaced.
Highly Likely

03 - Roper Dryer User Control and Display Board

The dryer control panel indicator lights are part of the user control and display board and cannot be replaced separately. If an control panel indicator light is not working, the user control and display board will need to be replaced.
Highly Likely

04 - Roper Dryer Touchpad and Control Panel

The dryer control panel indicator lights are part of the touchpad and control panel and cannot be replaced separately. If an control panel indicator light is not working, the entire touchpad and control panel assembly will need to be replaced.
Highly Likely

05 - Roper Dryer Door Switch

The dryer door switch will turn the interior light off when the door is closed and turn it back on when the door is opened. If the switch is defective, it may be unable to allow voltage to reach the light. You can use a multimeter to test the door switch for appropriate electrical continuity when actuated. If the switch doesn't provide appropriate continuity, it will need to be replaced.
Less Common

06 - Roper Dryer LED Light

The most likely cause of a dryer interior LED light not working is a defective light. Inspect the LED light for any visible damage or burn marks and replace as required.
Less Common

07 - Roper Dryer Light Assembly

The most likely cause of a dryer interior light not working is a defective light assembly. Inspect the assembly for any visible damage or burn marks and replace as required.
Less Common

Frequently Asked Questions

Dryer lights flashing or not working — why is the interior light out?
Dryer controls not working — can the control panel or touchpad cause the indicator lights to fail?
Dryer door won't close — could the door switch affect the interior light?
Dryer won't start — can a faulty door switch or control board prevent the dryer from starting?
How do I enter my model number or part number on RepairClinic.com to find the right replacement part?