Protect your unit with this replacement limit switch, part number 1013105, built for select ICP, Tempstar, Comfortmaker, Heil, or Arcoaire Furnace, Packaged Unit/RTU, or Air Handler models.
Grid is 1 inch square
1013105 Limit Switch
Manufacturer Part

1013105 Limit Switch

Genuine OEM Part # 1013105Alternative Part Number(s)
Manufacturer Part
Protect your unit with this replacement limit switch, part number 1013105, built for select ICP, Tempstar, Comfortmaker, Heil, or Arcoaire Furnace, Packaged Unit/RTU, or Air Handler models.
Grid is 1 inch square
1013105 Limit Switch
$9.15
Loading stock status
Loading stock status
Does this part fit my product?
Find your model number or log in to select it from your saved machines.
Protect your unit with this replacement limit switch, part number 1013105, built for select ICP, Tempstar, Comfortmaker, Heil, or Arcoaire Furnace, Packaged Unit/RTU, or Air Handler models.
Loading stock status
$9.15
start a live chat with Repair Clinic customer support

This part 1013105 is compatible with:

Product Type:
Air Handler, Furnace, Packaged Unit/RTU

Related Articles & Videos

02:47
Troubleshooting
Furnace Starts Then Stops — Furnace Troubleshooting
00:45
Troubleshooting
Replace Furnace Filters - Tech Tips from Repair Clinic
03:52
Troubleshooting
Furnace Not Heating — Furnace Troubleshooting
02:28
Troubleshooting
Furnace Blower Not Running — Furnace Troubleshooting
01:49
Troubleshooting
Furnace Noisy Or Loud — Furnace Troubleshooting
Frequently Bought with Limit Switch
5303935066 Igniter
297286803 Run Capacitor

Limit Switch Customer Reviews

Common Problems Fixed by the Limit Switch

Based on customer reports and repair data, this part commonly fixes these issues:

Very Likely

Furnace starts then stops

Likely

Air handler not heating

Possible

Air handler blower runs all the time

Possible

Furnace is frequently cycling/short cycling

Possible

Air handler is frequently cycling/short cycling

Possible

Furnace not heating

About the Limit Switch

The flame rollout limit switch monitors the heat surrounding the burners. If the inducer fan motor cannot draw enough air through the burners, or if the furnace is not venting properly, the rollout limit switch will open to halt the ignition sequence and prevent the furnace from heating. When this happens, the furnace will shut off after running for a few minutes. To determine if the flame rollout limit switch is defective, use a multimeter to test it for continuity. If the switch does not have continuity, replace it. Be aware that poor airflow through the burner is often a result of insufficient ventilation or a restricted exhaust vent. Make sure that your furnace is in a properly ventilated location and the exhaust vent is clear of obstructions.

Alternative Part Number(s)

Replaces Part Number 1084735